1/4" 15 PSI Safety Pressure Relief Valve

Part Number
PR-15

PR-15 - 1/4" 15 PSI Safety Pressure Relief Valve

Pressure Relief Valves- 15 PSI



TECHNICAL DATA



    TECHNICAL DATA


    • Inlet Orifice .312 Diameter
    • Flow Coefficient .45 @ 110% of nominal set pressure
    • Full rated flow is achieved by 110% of nominal set pressure
    • Crack pressure tolerance ± 5% of nominal set pressure
    • Zero leakage up to 95% of nominal set pressure
    • Brass bar stock construction with stainless steel springs
    • Temperature Range -320° to +400° F
    • Proof Pressure 1500 PSI

    TOP QUALITY



    Generant Relief Valve Is Engineered To Address the Specific Needs of Cryogenic Liquid Cylinder and Non-Coded Thermal Safety Relief Valve Applications.

    The High Flow and Excellent Reseal Characteristics Also Make This Valve Ideally Suitable For Many Industrial Applications.

    Poppet Design Completely Retains Soft Seal While Providing A Metal-To-Metal Back Up. This Poppet, Combined With a Burnished Seat, Insures Repeatable Performance Even When Subjected To Repeated Cycles at Cryogenic Temperatures.

    Valves Are Factory Preset, 100% Tested and Supplied Permanently Locked To Desired Set Point.

    CONSIDERATIONS


    • PTFE Seal, 50 PSI and above

    • Kel-F Seal, 100 PSI and above

    • Drain Hole omitted on CRVP

    • Flow is unaffected with 10% Back Pressure

    • Permanently Stamped with Full P/N and Pressure Setting

    • Can be supplied with Color Coded Labels in PSI and BAR

    • No Mounting Limitations

    Cleaned For Oxygen Service and Individually Packaged


    This procedure is in full compliance, and has been audited to the following recognized industry standards and specific customer quality assurance requirements:

    • Taylor-Wharton Gas Equipment Division, Quality Assurance
    • Union Carbide Linde Division, Engineering Standard Gs-38
    • Air Products and Chemicals Inc., Class AA Oxygen Cleaned 4wpi-Sw7003
    • Puritan Bennett Liquid Oxygen Group, Quality Assurance
    • Invacare Corporation, Inhalation Therapy Group, Quality Assurance

    Testing and Packaging Procedures Available Upon Request.

    OPTIONS:


  • Pipe- A- Way Adapter

  • Tamper Proof Ring (Ideal for Liquid Cylinders)

  • Seal Materials

  • Certified Test Results

Pop Stop Option For Pressure Reliefs


Pop Stop safely addresses the inconvenience of Liquid cylinders safety venting noise in enclosed environments. Designed to be used with Generant CRV series relief valves. Reference part # PR-MFLR.
* Muffler sold separately

Custom Pressure Settings Available, Give Customer Service a Call




WARNING:This product can expose you to chemicals including Lead which is known to the state of California to cause cancer, birth defects or reproductive harm. For more information, go to www.p65warnings.ca.gov.